Discontinued Product
LKO-1000
Index: WMGBLKO1000
LKO-1000 receiver
Technical Specification
Standard accessories
Basic in product
Files
- Technical Specification
Ingress protection IP54 Power supply 6x LR6 battery Operating temperature -20…+50°C Storage temperature -40…+70°C Humidity 95% Locator
Typical detection range
Mode Distance along conductor Power Mode length of conductor Radio Mode length of conductor Conductive Rod Mode ength of unwound rod Operating depth range
Mode Range Power Mode to 3 m / 10 ft Radio Mode to 2 m / 7 ft Transmitter Mode to 3 m / 10 ft Typical depth accuracy
Accuracy 10% of depth in line or Sonde 0.3 m to 3.0 m (1 ft to 10 ft) depth range Operating frequencies
Mode Frequency Power Mode 50 Hz or 60 Hz Radio Mode 15 kHz to 60 kHz 8 kHz Mode 8.192 (8 kHz) 33 kHz mode 32.768 (33 kHz) Auto mode Power mode and Radio mode Display Panel
- 48 segment bar graph
- 5 mode indicators
- Battery status indicator
- Line depth indicator
- Sonde depth indicator
- Bluetooth indicator
- Integrated backlight
- Annual service indicator
- 3 alpha numeric dot matrix displays 5 x 7
Keypad
2 membrane push buttons
Speakers
Dual speakers:
- Audio volumes: 85 dBA @ 30 cm
- Tone: Power, Radio and Auto mode: continuous tone (different pitch for each tone),8 kHz and 33 kHz mode: pulsed tone (different pitch for each tone). All five tones aredifferent.
- pneumatic headphone sockets are integrated
Internal battery
- Type: 6 x LR6 (AA) alkaline
- Typical operating time: 40 hrs intermittent use at 20°C / 68°F; in 8 kHz mode or 33 kHz mode
Instrument dimensions and weight
- dimensions: 760 mm x 250 mm x 85 mm; 30 Inches x 10 Inches x 3.4 Inches
- weight: 2.7 kg / 6 lbs (including batteries)
Environmental specifications
Type Description Temperature operating -20°C to +50°C
-4°F to +122°FTemperature storage -40°C to +70°C
-40°F to +158°FProtection against Water, Dust and Sand P54 (IEC 60529) Dust-protected Humidity 95% RH non condensing. The effects of condensation are to be effectively counteracted by periodically drying out the product. Conformity to national regulations
- FCC Part 15 (applicable in US)
- Hereby, Sonel S.A. declares that the Locator LKO-1000 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Class 1 equipment according European Directive 1999/5/EC (R&TTE) can be placed on the market and be put into service without restrictions in any EEA member state.
- The conformity for countries with other national regulations not covered by the FCC part 15 or European directive 1999/5/EC has to be approved prior to use and operation.
Frequency band
50 Hz to 60 kHz
Output power
Receive only
- Standard accessories
- Basic in product
- Files