      Producto retirado de la oferta

      PAT-815 digital meter is used to measure the parameters of electrical equipment (power tools, white goods, etc.) which determine their safety: resistance of protective conductors, insulation resistance, continuity of connections, leakage current, power, automatic measurement of all RCD parameters.

      PAT-815 can be used to test the equipment performed in accordance with standards:

      • EN 60745-1 Hand-held motor-operated electric tools. Safety. General requirements
      • EN 61029 Safety of transportable motor-operated electric tools - General requirements
      • EN 60335-1 Household and similar electrical appliances -Safety -Part 1: General requirements
      • EN 60950 Safety of information technology equipment (IT Equipment)
      • AS/NZS 3760:2010  In-service safety inspection and testing of electrical equipment
      • VDE 0404-1 Prüf - und Messeinrichtungen zum Prüfen der elektrischen Sicherheit von elektrischen Geräten. Teil 1: Allgemeine Anforderungen
      • VDE 0404-2 Prüf - und Messeinrichtungen zum Prüfen der elektrischen Sicherheit von elektrischen Geräten. Teil 2: Prüfeinrichtungen für Prüfungen nach Instandsetzung, Änderung oder für Wiederholungsprüfungen
      • VDE 0701-0702 Prüfung nach Instandsetzung, Änderung elektrischer Geräte. Wiederholungsprüfung elektrischer Geräte. Allgemeine Anforderungen für die elektrische Sicherheit
    • Datos técnicos

      Common features of the instruments:

      • measurement of protective conductor resistance with the currents: 200 mA, 10 A , 25 A ( protection class I),
      • measurement of insulation resistance – three measurement voltages: 100 V,  250 V and 500 V,
      • RCD testing,
      • measurement of equivalent leakage current,
      • measurement of residual leakage current,
      • measurement of touch leakage current,
      • measurement of power,
      • measurement of current consumption,
      • IEC lead test,
      • measurement of mains voltage and frequency.

      Other features:

      • intuitive user interface,
      • typing with QWERTY keyboard on the large and clear touch display,
      • manual tests and auto tests, the ability to describe auto test with standards or any name,
      • automatic measurement of RCD parameters,
      • automatic measurement range selection,
      • cooperation with a barcode reader and printer,
      • support for barcode reader (including 2D), readings of the original serial numbers for the appliances and registration codes and auto test codes,
      • the results can be printed (also automatically after every measurement), reports (works with the printer), two labels can be printed after a single test (for the device and a removable wire),
      • build-in help with instructions how to connect test equipment and how to perform measurement,
      • option to skip single measurement in the auto test, with the recording that choice of skipping of specified measurement was made conscious, the option does not apply to build-in auto tests,
      • description of test equipment, measurement location, customer data, assigning the serial number of the device under test and the index can be stored in meter memory, ability to write notes about the device under the test 
      • base of the appliances, customers, description of the equipment and damage.
      • ability to create many user accounts with log-in function (as an option),
      • supports USB flash drive;
      • communication with PC via USB,
      • works with the program Sonel Reader and Sonel PAT (option); measurement  and settings configuration from the meter and also from PC, data analysis.
      • professional software for data processing and reporting.

      Measurement of protective earth conductor resistance I=200mA (protection class I)

      Display rangeResolutionAccuracy
      0,00...0,99 Ω ±(4% m.v. + 2 digits)
      1,00...19,99 Ω0,01 Ω±(4% m.v.  + 3 digits)
      • test current: ≥200 mA for R = 0,2 Ω …1,99 Ω
      • adjustable measurement time: 1 s…60 s with1 s resolution
      • adjustable limit

      Measurement of protective earth conductor resistance I=10A (protection class I)

      Display rangeResolutionAccuracy
      0...999 mΩ1 mΩ±(3% m.v. + 4 digits)
      1,00...1,99 Ω0,01 Ω±(3% m.v. + 4 digits)
      • test current: ≥ 10 A for R ≤ 0,5 Ω
      • adjustable measurement time: 1 s…60 s with1 s resolution
      • technical method
      • adjustable limit

      Measurement of protective earth conductor resistance I=25A (protection class I)

      Display rangeResolutionAccuracy
      0...999 mΩ1 mΩ±(3% m.v. + 4 digits)
      1,00...1,99 Ω0,01 Ω±(3% m.v. + 4 digits)
      • test current: ≥ 25 A for R ≤ 0,2 Ω
      • adjustable measurement time: 1 s…60 s with1 s resolution
      • adjustable limit

      Measurement of insulation resistance 
      Measurement range according to IEC 61557-2 for:

      • UN=100 V: 100 kΩ...99,9 MΩ
      • UN=250 V: 250 kΩ...199,9 MΩ
      • UN=500 V: 500 kΩ...599,9 MΩ
      UNDisplay rangeResolutionAccuracy
      100V0...1999 kΩ1 kΩ±(5% m.v. + 8 digits)
      100V2,0...19,99 MΩ0,01 MΩ±(5% m.v. + 8 digits)
      100V20,0...99,9 MΩ0,1 MΩ±(5% m.v. + 8 digits)
      250V0...1999 kΩ1 kΩ±(5% m.v. + 8 digits)
      250V2,00...19,99 MΩ0,01 MΩ±(5% m.v. + 8 digits)
      250V20,0...199,9 MΩ0,1 MΩ±(5% m.v. + 8 digits)
      500 V0...1999 kΩ1 kΩ±(5% m.v. + 8 digits)
      500 V2...19,99 MΩ0,01MΩ±(5% m.v. + 8 digits)
      500 V20,0...599,9 MΩ0,1 MΩ±(5% m.v. + 8 digits)
      • nominal current: min 1 mA…1,4 mA
      • adjustable limit
      • adjustable measurement time: 3 s…3 min with 1 s resolution
      • automatic discharge of the capacity of the tested device after measurement
      • protection against measuring live devices

      Measurement of PE and residual leakage current:

      Display rangeResolutionAccuracy
      0,00...3,99 mA0,01 mA±(5% m.v. + 2  digits)
      4,0...19,9 mA0,1 mA±(5% m.v. + 2  digits)
      • adjustable limit
      • adjustable measurement time:1...60s  with1s resolution

      Measurement of equivalent leakage current:

      Display rangeResolutionAccuracy
      0,00...3,99 mA0,01 mA±(5% m.v. + 2 digits)
      4,0...19,9 mA0,1mA±(5% m.v. + 2 digits)
      • open circuit voltage 25...50 V
      • adjustable limit
      • adjustable measurement time:1...60s  with1s resolution

      Measurement of touch leakage current:

      Display rangeResolutionAccuracy
      0,00...4,999 mA0,001 mA±(5% m.v. + 3 digits)
      • adjustable limit
      • adjustable measurement time:1...60s  with1s resolution

      Measurement of power S:

      Display rangeResolutionAccuracy
      0...999 VA1 VA±(5% m.v. + 3 digits) ±(8 % m.v. + 5 digits)*
      1...3,99 kVA0,01 kVA±(5% m.v. + 3 digits) ±(8 % m.v. + 5 digits)*
      • adjustable measurement time:1...60s  with1s resolution
      • * - for measurement with clamps

      Measurement of power P:

      Display rangeResolutionAccuracy
      0...999 W1 W±(5% m.v. + 3 digits) ±(8 % m.v. + 5 digits)*
      1...3,99 kW0,01 kW±(5% m.v. + 3 digits) ±(8 % m.v. + 5 digits)*
      • adjustable measurement time:1...60s  with1s resolution
      • * - for measurement with clamps

      Power factor PF:

      Display rangeResolutionAccuracy
      0,00...1,000,01±(10% m.v. + 5 digits)
      • adjustable measurement time:1...60s  with1s resolution

      Measurement of current consumption:

      Display rangeResolutionAccuracy
      0,00...15,99 A0,01 A±(2% m.v. + 3 digits)
      • adjustable measurement time:1...60s  with1s resolution

      Voltage measurement:

      Display rangeResolutionAccuracy
      195,0…265,0 V0,1V±(2% m.v. + 2 digits)

      Frequency measurement:

      Display rangeResolutionAccuracy
      45,0 Hz...55,0 Hz0,1 Hz±(2% m.v. + 2 digits)

      Pomiar napięcia PE sieci:

      Display rangeResolutionAccuracy*
      0,0...59,9 V0,1 V±(2% m.v. + 2 digits)
      • * - for U < 5 V accuracy is not specified

      Measurements of RCD parameters
      RCD trigger and response time test tA
      Test range according to IEC 61557: 0 ms ... to the upper limit of displayed value

      RCD typeFactorRangeResolutionAccuracy
      General0,5*IΔn0...300 ms1 ms± (2% m.v. + 2 digits) (for RCD of IΔn=10 mA and the measurement with 0,5xIΔn accuracy is: ±(2% m.v.+ 3 digits)
      General1*IΔn0...300 ms1 ms± (2% m.v. + 2 digits) (for RCD of IΔn=10 mA and the measurement with 0,5xIΔn accuracy is: ±(2% m.v.+ 3 digits)
      General2*IΔn0...150 ms1 ms± (2% m.v. + 2 digits) (for RCD of IΔn=10 mA and the measurement with 0,5xIΔn accuracy is: ±(2% m.v.+ 3 digits)
      General5*IΔn0...40 ms1 ms± (2% m.v. + 2 digits) (for RCD of IΔn=10 mA and the measurement with 0,5xIΔn accuracy is: ±(2% m.v.+ 3 digits)

      Measurement of RCD disconnection current IA for sinusoidal differential current
      Test range according to IEC 61557: (0,3...1,0)IΔn

      Selected  nominal  current of RCD RangeResolutionTest currentBasic  uncertainty
      10 mA3,3...10,0 mA0,1 mA0,3 x IΔ..1,0 x IΔ± 5%IΔn
      15 mA4,5...15,0 mA0,1 mA0,3 x IΔ..1,0 x IΔ± 5%IΔn
      30 mA9,0...30,0 mA0,1 mA0,3 x IΔ..1,0 x IΔ± 5%IΔn
      • it is possible to start the measurement from the positive of the negative half of forced leakage current
      • test current passage time max. 3200 ms
      • automatic measurement of RCD disconnection time (tA) and disconnection current 
      • measurement for: 0,5IΔn, 1IΔn, 2IΔn i 5IΔn,

      Electrical safety:

      • measurement category: II 300V acc.to EN 61010-1
      • enclosure protection rating acc. to EN 60529: IP40 (IP67 with lid closed)

      Other technical specification:

      • power supply: 195 V...265V, 50Hz
      • load current: max. 16A (230V)
      • data transmission to PC: USB 2.0, WiFi
      • dimensions: 330 x 235 x 120 mm
      • weight: approx. 6,2 kg
      • operating temperature: -10°...+50°C
      • storage temperature: -20°...+70°C
      • humidity:20...80%
      • display: TFT 7'’ 800x480
    • Accesorios estándar
    • Accesorios adicionales
    • Archivos
      • Cambios en la versión 4.0.25.0 respecto a la anterior:

        • Exportación a Excel mejorada para el dispositivo MRU‑200-GPS.
        • Lectura mejorada de datos de contadores con el sistema MeasureEffect.
        • Lectura mejorada de archivos del dispositivo MPI‑535.
        • Mejora del mecanismo general de exportación a Excel.

        Cambios en la versión 4.0.24.0 respecto a la anterior:

        • Se ha mejorado la exportación de datos a Excel.
        • En la versión 1.26.1.103 se ha optimizado la integración de los medidores con el sistema MeasureEffect.
        • Se ha actualizado la visualización de los resultados del MRU-120.
        • Se ha mejorado la facilidad de uso del MZC-304F.

        Cambios en la versión 4.0.23.0 respecto a la anterior:

        • Se ha mejorado la comunicación con el MPI-540.
        • Se han actualizado las bibliotecas y se han aplicado correcciones menores.
        • Se ha añadido compatibilidad con los modelos MMR-6500E y MMR-6700E.

        Cambios en la versión 4.0.22.0 respecto a la anterior:

        • Mejora de la comunicación con el MRU-30.
        • Se ha añadido la lectura del número de serie para el MPI-520 y el MPI-525.
        • Correcciones relacionadas con la representación de gráficos y las traducciones.
        • Pequeñas mejoras que aumentan la estabilidad general del programa.

        Cambios en la versión 4.0.21.0 respecto a la anterior:

        • Mejora de la visibilidad de la ventana de selección de clientes.

        Cambios en la versión 4.0.20.0 respecto a la anterior:

        • Mejora de la comunicación con los medidores.
        • Mejora de la generación de gráficos.
        • Mejora de la visibilidad de la ventana de selección de clientes.
      • Cambios en la versión 4.0.24.0 respecto a la anterior:

        • Se ha mejorado la exportación de datos a Excel.
        • En la versión 1.26.1.103 se ha optimizado la integración de los medidores con el sistema MeasureEffect.
        • Se ha actualizado la visualización de los resultados del MRU-120.
        • Se ha mejorado la facilidad de uso del MZC-304F.

        Cambios en la versión 4.0.23.0 respecto a la anterior:

        • Se ha mejorado la comunicación con el MPI-540.
        • Se han actualizado las bibliotecas y se han aplicado correcciones menores.
        • Se ha añadido compatibilidad con los modelos MMR-6500E y MMR-6700E.

        Cambios en la versión 4.0.22.0 respecto a la anterior:

        • Mejora de la comunicación con el MRU-30.
        • Se ha añadido la lectura del número de serie para el MPI-520 y el MPI-525.
        • Correcciones relacionadas con la representación de gráficos y las traducciones.
        • Pequeñas mejoras que aumentan la estabilidad general del programa.

        Cambios en la versión 4.0.21.0 respecto a la anterior:

        • Mejora de la visibilidad de la ventana de selección de clientes.

        Cambios en la versión 4.0.20.0 respecto a la anterior:

        • Mejora de la comunicación con los medidores.
        • Mejora de la generación de gráficos.
        • Mejora de la visibilidad de la ventana de selección de clientes.
      • Firmware PAT-815 (2308)

        Cambios en la versión 2308 respecto a la anterior:

        • Medición mejorada de Rpe 200mA IEC.
        • Se han subido las versiones correctas de los procedimientos automáticos para medidores PAT-820L.