LKO-1000

LKO-1000
Index: WMGBLKO1000
LKO-1000 receiver
Technical Specification
Files
  • Technical Specification
    Ingress protection IP54
    Power supply 6x LR6 battery
    Operating temperature -20…+50°C
    Storage temperature -40…+70°C
    Humidity 95%

    Locator

    Typical detection range

     


    Mode Distance along conductor
    Power Mode length of conductor
    Radio Mode length of conductor
    Conductive Rod Mode ength of unwound rod

    Operating depth range


    Mode Range
    Power Mode to 3 m / 10 ft
    Radio Mode to 2 m / 7 ft
    Transmitter Mode to 3 m / 10 ft

    Typical depth accuracy


    Accuracy
    10% of depth in line or Sonde
    0.3 m to 3.0 m (1 ft to 10 ft) depth range

    Operating frequencies


    Mode Frequency
    Power Mode 50 Hz or 60 Hz
    Radio Mode 15 kHz to 60 kHz
    8 kHz Mode 8.192 (8 kHz)
    33 kHz mode 32.768 (33 kHz)
    Auto mode Power mode and Radio mode

    Display Panel


    • 48 segment bar graph
    • 5 mode indicators
    • Battery status indicator
    • Line depth indicator
    • Sonde depth indicator
    • Bluetooth indicator
    • Integrated backlight
    • Annual service indicator
    • 3 alpha numeric dot matrix displays 5 x 7

    Keypad


    2 membrane push buttons

    Speakers


    Dual speakers:

    • Audio volumes: 85 dBA @ 30 cm
    • Tone: Power, Radio and Auto mode: continuous tone (different pitch for each tone),8 kHz and 33 kHz mode: pulsed tone (different pitch for each tone). All five tones aredifferent.
    • pneumatic headphone sockets are integrated

    Internal battery


    • Type: 6 x LR6 (AA) alkaline
    • Typical operating time: 40 hrs intermittent use at 20°C / 68°F; in 8 kHz mode or 33 kHz mode

    Instrument dimensions and weight


    • dimensions: 760 mm x 250 mm x 85 mm; 30 Inches x 10 Inches x 3.4 Inches
    • weight: 2.7 kg / 6 lbs (including batteries)

     

    Environmental specifications


    Type Description
    Temperature operating -20°C to +50°C
    -4°F to +122°F
    Temperature storage -40°C to +70°C
    -40°F to +158°F
    Protection against Water, Dust and Sand P54 (IEC 60529) Dust-protected
    Humidity 95% RH non condensing. The effects of condensation are to be effectively counteracted by periodically drying out the product.

    Conformity to national regulations


    • FCC Part 15 (applicable in US)
    • Hereby, Sonel S.A. declares that the Locator LKO-1000 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Class 1 equipment according European Directive 1999/5/EC (R&TTE) can be placed on the market and be put into service without restrictions in any EEA member state.
    • The conformity for countries with other national regulations not covered by the FCC part 15 or European directive 1999/5/EC has to be approved prior to use and operation.

    Frequency band


    50 Hz to 60 kHz

    Output power


    Receive only

  • Files

Standard accessories

Slide 1 of 3

Basic in product